  for reference date of issue: march 17, 2011 omron corporation omron relay&devices corporation specifications this specification sheet is for reference only, please reques t it again if a specification for receipt is necessary. distribution copy customer 1 sales handled by
[ ] for receipt [*] for reference spec. no.: (1/9) date of first issue: march 17, 2011 date of revised issue: ---------- omron corporation omron relay & devices corporation issued by march 17, 2011 m.miura checked by march 17, 2011 t.fukuda authorized by march,17,2011 k.kawahara product specification name: terminal relay model: g6c-4b(n)(d) item: all ratings after the confirmation for all description on the specification shee t, your kindly cooperation with sending back the original copy with y our acknowledgement to us is required until --- --, ---- . receipt stamp (for receipt purpose only) submitted stamp stamp of sales office stamp of an agency please accept handling of this specification sheet as for reference use if no reply received. distribution revision history copies see item -- customer 1 sales office: ( ) --- for return ---
no. (2/8) 1. classification terminal relay 2. construction 2.1 outline dimensions see item 14. 2.2 connection diagram ----- 2.3 contact configuration spst-no+spst-nc x 2 3. standards 3.1 approved standards ul: ul508( e87929), csa: c22.2 no.14(lr35535), 3.2 conformed standards ------- 4. ratings (per g6c relay 1pc.) 4.1 coil ratings see table 1 (1) rated voltage and frequency --- vdc --- hz (2) rated current set --- ma --- hz(at v, on hz) reset --- ma --- hz(at v, on hz) (3) coil resistance set --- ma --- hz(at v, on hz) reset --- ma --- hz(at v, on hz) (4) operate voltage --- to --- % of the rated voltage (5) rated power consumption approx. --- w max. 4.2 contact ratings (1) rated load resistive load 250 vac 8 a 30 vdc 8 a inductive load 250 vac 3.5 a (p.f. = 0.4 ) 30 vdc 3.5 a (l/r = 7 ms) (2) rated carry current 8 a (3) max. switching voltage 380 vac 125 vdc (4) max. switching current resistive load ac 8 a dc 8 a inductive load ac 8 a (p.f. = 0.4 ) dc 8 a (l/r = 7 ms) (5) max. switching capacity resistive load ac 2000 va dc 240 w inductive load ac 875 va (p.f. = 0.4 ) dc 170 w (l/r = 7 ms) 5. characteristics (initial value) 5.1 contact resistance 100 m max. (initial value) measured by the voltage drop method with dc5 v 1 a applied
no. (3/8) 5.2 must operate voltage(or current) --- ( v ma) max. must set voltage(or current) see table 1 5.3 must release voltage(or current) --- ( v ma) max. must reset voltage(or current) see table 1 5.4 operate time set time 10 ms max. (at rated voltage) 5.5 release time reset time 10 (g6b-4b/-4bn) ms max. (at rated voltage) 15 (g6b--4bnd) ms max. (at rated voltage) 5.6 insulation resistance 1000 m min. (at 500vdc) 5.7 dielectric strengt h (at 50/60hz for 1 minute) (1) between coil contacts of the different polarity 250 vac (2) between contact terminal s of the different polarity 2000 vac (3) between contact terminals of the same polarity 1000 vac (4) between coil and contacts 2000 vac 5.8 temperature rise (1)coil 50 c max. (by the coil resistance method) ambient temperature 55c applied voltage of coil: 100 % of rated voltage carry current of contact: 8 a (2)contact 65 c max. (by the coil thermometer method) ambient temperature 55c applied voltage of coil: 100 % of rated voltage carry current of contact: 8 a 5.9 vibration resistance (1) destruction must be free from any abnormality in both the construction and characteristics after the relay is held at a variable vibration of 0.75 mm single amplitude ( 1.5 mm double amplitude) at a vibration frequency of 10 to 55 to 10 hz in each direction for 2 hours. (2) malfunction contacts must not open for 1 ms or longer after the relay (when energized) is held at a variable vibration of 0.75 mm single amplitude ( 1.5 mm double amplitude) at a vibration frequency of 10 to 55 to 10 hz in each direction for 1 cycle. (when not energized) contacts must not open for 1 ms or longer after the relay is held at a variable vibration of 0.75 mm single amplitude ( 1.5 mm double amplitude) at a vibration frequency of 10 to 55 to 10 hz in each direction for 1 cycle.
no. (4/8) 5.10 shock resistance (1) destruction must be free from any abnormality in both t he construction and characteristics after the relay is subjected to a shock of 1000 m/s in each direction 5 times. (2) malfunction must be free from a contact opening of 1 ms or longer (when energized) after the relay is s ubjected to a shock of 100 m/s in each direction 5 times. (when not energized) must be free from a contact opening of 1 ms or longer after the relay is subjec ted to a shock of 100 m/s in each direction 5 times. 5.11 temperature resistance (1) heat resistance must be free fr om any abnormality in both the construction and characteristics after the relay is left in a temperature of 85 2 c for 16 hours and then in room temperature and humidity for 2 hours. (2) cold resistance must be free fo rm any abnormality in both the construction and characteristics after the relay is left in a temperature of -55 3 c for 72 hours and then in room temperature and humidity for 2 hours. 5.12 moisture resistance must be free fr om any abnormality in both the construction and characteristics after the relay is left in a humidity of 90 to 95 %rh for 48 hours at a temperature of 40 2 c, and then in room temperature and humidity for 2 hours. insulation resistance, however, must be 5 m min. 5.13 terminal strength must be free from any abnormality after a tensile stress of 49n is applied to the terminal in the vertical direction for 1 seconds. any deformation of the termi nal by the load shall not be regarded as a mechanical damage. * appropriate clamp torque: 0.78 to 1.18 n ? m 5.14 insert stress ----- n 5.15 tensile stress ----- n 5.16 mounting strength must be no damaging nor shaky m ounting part after a tensile stress of 49n is applied to the horizontal direction and for 1 second. (for a rail direction, 9.8 n min.)
no. (5/8) 5.17 endurance (1) mechanical endurance 50,000,000 operations min. (under no load at operating frequency of 18,000 operations/h) (2) electrical endurance 100,000 operations min. (under rated load at operating frequency of 1,800 operations/h) (3) endurance of insert and remove --- times min. 5.18 failure rate p level 60 = 0.1 10 -6 (reference value) condition: resistive load 5 vdc 10 ma switching ----- operations/h 6. standard test conditions unless otherwise s pecified, the values described in this specification obt ained under the following conditions as standard. 6.1 temperature 23c 6.2 humidity 65% rh 7. storage conditions 7.1 environments (1) must be in a location where the produc t or container is not exposed to corrosive gas such as hydrogen sulfide gas or salty air. (2) must be in a location where no visible dust exists. (3) must be in a location without direct sunlight. any stress to the product which may result in the deformation or change in quality of the product is not allowed. 8. operating conditions use the product under the following conditions 8.1 temperature -25 to +55 c (without icing nor condensation) 8.2 humidity 45 to 85 % rh 8.3 mounting direction --- 8.4 environments (1) must be in a location where the produc t or container is not exposed to corrosive gas such as hydrogen sulfide gas or salty air. (2) must be in a location where no visible dust exists. (3) must be in a location without direct sunlight. any stress to the product which may result in the deformation or change in quality of the product is not allowed.
no. (6/8) 9. changing the content s of this document omron reserves the right to change the specificati ons except for the ratings, performance, structure, outer dimensio ns, and mounting dimensions. 10. valid term of this specification this specification becom es invalid if you do not contact us after a lapse of 1 year from the issue date of this specification. 11.handling precautions do not drop or give a shock to the product to maintain the initial performance when handling it. 12. other information to customers purchasing omron products agreement when placing orders thank you for using omron products. unless otherwise specified in a written es timate, contract, or spec ifications, the following conditions and warranty in formation apply when an omron cont rol device (hereafter called ?omron product?) is ordered from catal ogs. ordering an omron product implies consent to these terms and conditions. 1. warranty (1) warranty period the warranty period for an omron produc t is one year from either the date of purchase or the date on which the omron pr oduct is delivered to t he specified location. (2) extent of warranty if an omron product is subject to a failure for which omron is responsible during the warranty period, either a replacement product will be provided or the defective product will be repaired free of charge at t he place of purchase. this warranty, however, will not cover problems that occur as a result of any of the following. a) using the omron product under conditions or in an environment not described in catalogs or in the specifications, or not operating the omron product according to the instructions contai ned in catalogs or in the specifications. b) problem caused by something other than the omron product. c) modifications or repairs performed by a party other than omron. d) using the omron prod uct for other than its designed purpose. e) problems that could not have bee n foreseen with the level of science and technology that existed at t he time the omron product was shipped. f) problems caused by an act of g od or other circumstances for which omron is not responsible. this warranty covers only the omron product itself. it does not cover any other damages that may occur directly or indirectly as a result of a problem with the omron product.
no. (7/8) 2. limitations of liability (1) omron shall not be responsible for spec ial, indirect, or consequential damages originating in an omron product. (2) for programmable omron products , omron does not accept responsibility for any programming that is performed by a party other than omron, or for any results arising from that programming. 3. applicable conditions (1) when using omron products in combination with other products, it is the user?s responsibility to c onfirm compliance with a ll applicable standards and regulations. it is also the user?s responsibilit y to confirm the suitability of the omron products for the system, devices, and equipment t hat are being used. omron accepts no responsibility for the suitability of omron produc ts used in combination with other products. (2) when using omron products in any of the following applicat ions, consult an omron representative and c heck specifications to allow suff icient leeway in ratings and performance, and to implement suit able safety measures, such as safety circuits, to minimize danger in the event of an accident. a) outdoor applications , applications with potential for chem ical contaminati on or electrical interference, or application under conditions or environments not described in catalogs. b) nuclear control systems, railr oad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, or equipment regulated by government or industrial standards. c) other systems, machines, and equipment that may have a serious influence on human life and property. d) equipment requiring a high level of reliability, such as gas, water, or electrical supply systems, and systems that operate 24 hours a day. e) other applications requiring a high le vel of safety, corresponding to points i) to iv), above. (3) when omron products are used in an application that could pos e significant risk to human life or property, the overall sy stem must be designed so that the required safety can be ensured by providing notic e of the danger and incorporating redundancy into the design. make sure that omro n products are appropriately wired and mounted to serve their intended purpose in the overall system. (4) application examples provided in cata logs are for reference only. confirm functionality and safety before actua lly using the devices and equipment. (5) to prevent unexpected problems from arising due to the omron product being used incorrectly by the customer or any ot her party, make sure that you understand and carefully observe all of the relevant prohibitions and precautions. 4. changes to specifications specifications and accessories to the products in catalogs may be changed as needed to improve the products or for any other reas on. check with your omron representative for the actual specific ations for omron products at the time of purchase. 5. extent of service the price of an omron product does not include service costs, such as dispatching technical staff. if you wish for service, pl ease consult with your omron representative.
no. (8/8) 6. prices the standard prices listed in the catalog are for reference only, and do not indicate fixed purchase prices. the pr ices also do not include tax. 7. applicability the above information assumes that bus iness and product applicat ion will be conducted in japan. for business and application outside of jap an, consult with your omron representative. 13. others 13.1 coil ratings (table 1) note: 1. rated current and coil resistance were measured at a coil temperature 23c with a tolerance 10%. 2. the value in ( ) of rated cu rrent is included led current of ?4bn type. the value in < > of rated current is included led current of ?4bnd type. 3. the value in ( ) of operate voltage is for ?4bn/-4bnd type (with operating indicator type). 4. operating characteristics were measured at a coil temperature of 23c. 5. the maximum allowable voltage is t he maximum value of the allowable voltage range for the relay coil operating powe r supply. there is no continuous allowance. 13.2 g6c models are connected direct ly to boards to increase reli ability and the relays are thus not replaceable. 14. dimensions note: all units are millimeters unless otherwise indicated. operate voltage release voltage max. voltage rated voltage (v) rated current (ma) coil resistance ( ) % of rated voltage power consumption (mw) dc5 40 (42) <36> 125 dc12 16.7 (18.6) <17.7> 720 dc24 8.3 (10.5) <10.2> 2,880 70 max. (80 max.) 10 min. 130 approx. 200


▲Up To Search▲   

 
Price & Availability of G6C-4BN-DC24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X